Specifications
Performance Specifications
The following table shows the performance specifications for DL-RS1A.
* The number of connectable sensor amplifiers varies depending on the model to be connected.
• When configured with the GT2-70 Series units: Up to 15 units (including the master unit)
• GT2-100 (large display type): 1 unit (up to 11 sensor heads can be added to one sensor amplifier by connecting
the head expansion board)
Communication Specifications
The following table shows the communication specifications for DL-RS1A.
Item Specifications
Model DL-RS1A
Power supply voltage
20 to 30 VDC, including 10% ripple (P-P). Class2
(Supplied from the connected sensor amplifier)
Current consumption 25 mA max.
Number of connectable
sensor amplifiers
Varies depending on the model*
Indicators
2 communication status indicators (green), alarm indicator (red), power indicator
(green)
Environ-
mental
Ambient
temperature
-10 to +55°C (No freezing)
Relative
humidity
35 to 85% RH (No condensation)
Vibration 10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes
Material Main unit housing: polycarbonate
Weight Approx. 53 g
Accessories
Instruction manual, 2 end units, expansion connector cover, switch protection
sticker
Item Specifications
Communication method Full duplex
Synchronization method Asynchronous
Transmission code
ASCII
Communication speed
(Baud rate)
2400, 4800, 9600, 19200, 38400 bit/s
(Factory default: 9600 bit/s)
Data bit length 7 or 8 bits (Factory default: 8 bits)
Parity check None, even, odd (Factory default: none)
Stop bit length 1 bit
Data delimiter
Receive: automatically detect CR or CR + LF
Send: fixed to CR + LF
Comentarios a estos manuales