Keyence PX-10 Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
Connecting the Cables and the IDC Connector
Note
When the cable length of the sensor head is changed, be sure to connect the amplifier
to check that it operates correctly.
1 Manipulate the end of the cables as shown in the following figure.
Peel back the insulation 10 mm from the end. (Do not strip the wires in the core.)
Twist the base of the shielded wire at least five times so it does not unravel,
and bend it 90° to the side.
* Be careful not to twist the core wires along with the shielded wire.
If the wires become twisted, untwist them slightly and pull the core wires apart
from the shielded wires.
2 Align the core wires with the same color as indicated by the sticker on the IDC
connector and insert the wires as shown below.
Insert the two wires (one black and one white) for the black cable (receiver
side) into the connector completely.
The red wire for the gray cable (transmitter side) cannot be inserted
completely, but insert it as far as it can go.
Twist the shielded wires in the direction of the arrow while pulling them into
the ditches.
3 Close the IDC connector, crimp it tight with pliers or a similar tool, and push
down on the top to lock it shut.
Note
Be careful not to crush the raised portion shown in the diagram when using pliers.
4 Use wire cutters or a similar tool to trim off the wires sticking out of the IDC
connector.
Note
Do not install the connectors more than two times. If the installation exceeds twice,
purchase OP-77758 (two connectors) separately.
If "ErH" appears on the amplifier even when using pliers to crimp the connector,
press the cable (part A) between the metallic contacts with a thin tool such as a
flathead screwdriver to crimp the cable more firmly.
Mounting the Connector
1 Install the IDC connector tight with Cap B.
2 Slide the packing and the mounting fixture in the direction of the arrow to
combine them.
Insert the packing into the hole in Cap B and combine the parts so that the
raised portion on Cap B lines up with the notch on the mounting fixture.
3 Push Cap A in the direction of the arrow and turn it clockwise to lock it into
place. Tighten Cap A while pushing on the IDC connector as shown in the
diagram below.
12
90°
Core wires
90°
Shielded wire
*
Red
White
Black
Shielded wire
Raised portion
Raised portion
Back Front
Part A
Metallic
contact
Cable
Metallic
contact
IDC connector
Cap B
Mounting fixture
Cap B
Packing
Packing
Raised
portion
Cutout
Tighten the parts until there
is no gap between them.
Cap A
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales