KEYENCE CORPORATION. Vision System Division
‐ 10 ‐ www.keyence.com
Outputting the individual status of each tool (parallel I/O)
Perform the following wiring to output the individual status of tools from the I/O terminal (parallel I/O interface).
This section describes the necessary terminal (outputs: OUT6 to 21 (OUT_DATA0 to 15), COMOUT2) wiring for
outputting the individual status of tools from the I/O terminal. (The parallel I/O cable, OP
‐51657, i
s sold
separately)
1. Wiring
Suitable wire: AWG 16 to 28
Terminal block screw torque: 0.25 Nm or less
Controller (parallel I/O interface)
Output circuit diagram (NPN output type)
Output circuit diagram (PNP output type, controllers with a "P" at the end of the part number)
‐ Maximum applied voltage: 30 V
‐ Ma
ximum sink current: 50 mA
‐ Le
akage current: 0.1 mA or less
‐ Re
sidual voltage:
1.4 V
or less (50 mA)
1.0 V or less (20 mA)
‐ Max
imum applied voltage: 30 V
‐ Ma
ximum sink current: 50 mA
‐ Le
akage current: 0.1 mA or less
‐ Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
(No. 1, 2)
(No. 5)
(No. 5)
(No. 1, 2)
Comentarios a estos manuales